Condensate evaporation tray without an opening (300x222x36.5 mm) KP-BCPT1N – AiFO

Technical drawing

Condensate evaporation tray · AiFO

Condensate evaporation tray KP-BCPT1N – 300x222x36.5 mm

Item no. KP-BCPT1N · EAN 2010000117408

  • made of polymers
  • vertical tray
  • version with a heater hole KP-BCPT1
Material
polycarbonate
capacity
1,65 l

In brief

  • KP-BCPT1N is the closed variant of the flat 300 × 222 × 36.5 mm tray with a capacity of 1.65 l – without the heater opening.
  • A polymer body, vertical variant, footprint identical to KP-BCPT1.
  • No heater passage means one fewer potential point of leakage.
  • Installation comes down to sliding the tray into place – without connecting anything.
Data sheet PDF, p. 90

Prices and stock levels are in the B2B shop. Thermoformed made-to-measure parts are quoted individually – a drawing or the installation dimensions is enough.

Condensate evaporation tray without an opening (300x222x36.5 mm) KP-BCPT1N – how to choose the right one

KP-BCPT1N is a polymer condensate evaporation tray measuring 300 × 222 × 36.5 mm with a capacity of 1.65 l, made without the heater opening. It's the same body as KP-BCPT1 – the lowest-profile tank with a capacity over a litre and a half in this category – intended to work purely on passive evaporation.

Choosing the closed version isn't only a matter of price. In every tray, the heater's passage through the tank wall is the point with the highest risk of leaking, because the seal works submerged and through heating cycles. Where there won't be a heater anyway, a single-piece moulding eliminates this failure point and simplifies installation in the condensing unit compartment.

Where to start: installation height, capacity, heater – we explained it in the selection guide for this category.

Where it works

  • Installations where condensate is emptied during servicing
  • Installations with a clearance of around 4 cm and passive evaporation
  • Tanks emptied by hand as part of periodic servicing
  • Installations where additional electrical components aren't permitted in the condensing unit compartment

FAQ

Frequently asked questions

Have not found your answer? Give the installation dimensions and the amount of condensate – we will select the tray and the heater.

Ask a question
Can an opening for a heater be drilled into KP-BCPT1N on site?

It's not worth it. The opening not only has to be made, but sealed so that it withstands permanent submersion and cyclical heating; in series production this is done in the mould, not with a drill on site. The version with a factory heater passage is KP-BCPT1, with an identical 300 × 222 × 36.5 mm footprint and the same 1.65 l capacity.

How often does a tray without a heater need emptying?

This depends on the condensate build-up in the specific unit, not on the tray model. A practical method: after start-up, check the water level after a day of full load and calculate how many days 1.65 l lasts. If it comes out shorter than the interval between services, condensate needs to be drained away from the unit, or a version with a heater is needed.

Enquiry

We will quote Condensate evaporation tray without an opening (300x222x36.5 mm) KP-BCPT1N for your appliance

Give the dimensions of the space available and the amount of condensate – we will reply with a selection and a quote.

B2B shop

Get in touch